| Data Sheet ADDA-100 | |
| Galvanically isolated from mains line and earth | |
| Four independent A/D converters: | Input voltage range: ± 10 V Input resistance: 2 kOhm All inputs are measured at exactly the same time by simultaneously triggered A/D converters - 16 bit resolution - 100 kHz maximum conversion rate - 4th order Butterworth filter at each A/D converter analog input with fc = 100 kHz |
| Two independent D/A converters: | Output voltage range: ± 10 V Output voltage quantization steps: 0.305 mV Settling time: 500 ns |
| Real-time clock: | Real-time data acquisition with 10-6s time resolution |
| High-speed opto-isolated digital parallel interface: | |
| Opto-isolated digital input / output lines (+5 V / 8 mA) for readout of the four analog inputs, and for remote setting of the two D/A outputs | |
| Signal propagation delay: | < 75 ns |
| Software: | |
| Simultaneous recording of the four analog inputs, remote setting of the two D/A outputs | The software runs under Windows NT 4.0 and other Windows derivatives. The software comes with a PC interface card (PCI bus) and a 2 m connecting cable between PC and ADDA-100. |
| Sampling rate: | 0.01 - 20000 samples per second |
| Oversampling: | dependent on sampling rate |
| Resolution and noise: | < ± 5 x 10-5 full scale range (at 50 samples per second, inputs connected to signal ground) |
| This page last updated on May 7, 2004 |